Maximum
SCPI Command:
FETCh:AFRF:MEASurement<Instance>:DIGital:TTL:BERate:MAXimum
CALCulate:AFRF:MEASurement<Instance>:DIGital:TTL:BERate:MAXimum
READ:AFRF:MEASurement<Instance>:DIGital:TTL:BERate:MAXimum
- class MaximumCls[source]
Maximum commands group definition. 3 total commands, 0 Subgroups, 3 group commands
- calculate() float [source]
# SCPI: CALCulate:AFRF:MEASurement<Instance>:DIGital:TTL:BERate:MAXimum value: float or bool = driver.afRf.measurement.digital.ttl.bitErrorRate.maximum.calculate()
Queries BER measurement results for the TTL path. CALCulate commands return error indicators instead of measurement values.
Use RsCma.reliability.last_value to read the updated reliability indicator.
- return:
ber: (float or boolean) Range: 0 % to 100 %, Unit: %
- fetch() float [source]
# SCPI: FETCh:AFRF:MEASurement<Instance>:DIGital:TTL:BERate:MAXimum value: float = driver.afRf.measurement.digital.ttl.bitErrorRate.maximum.fetch()
Queries BER measurement results for the TTL path. CALCulate commands return error indicators instead of measurement values.
Use RsCma.reliability.last_value to read the updated reliability indicator.
- return:
ber: Range: 0 % to 100 %, Unit: %
- read() float [source]
# SCPI: READ:AFRF:MEASurement<Instance>:DIGital:TTL:BERate:MAXimum value: float = driver.afRf.measurement.digital.ttl.bitErrorRate.maximum.read()
Queries BER measurement results for the TTL path. CALCulate commands return error indicators instead of measurement values.
Use RsCma.reliability.last_value to read the updated reliability indicator.
- return:
ber: Range: 0 % to 100 %, Unit: %