Delta
SCPI Command:
CONFigure:AFRF:MEASurement<Instance>:DEModulation:MDEPth:DELTa:MODE
CONFigure:AFRF:MEASurement<Instance>:DEModulation:MDEPth:DELTa:USER
CONFigure:AFRF:MEASurement<Instance>:DEModulation:MDEPth:DELTa:MEASured
- class DeltaCls[source]
Delta commands group definition. 4 total commands, 1 Subgroups, 3 group commands
- get_measured() float [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:DEModulation:MDEPth:DELTa:MEASured value: float = driver.configure.afRf.measurement.demodulation.modDepth.delta.get_measured()
Configures the measured reference value of the modulation depth for AM demodulation.
- return:
meas_val: Range: 0.01 % to 100.00 % , Unit: %
- get_mode() DeltaMode [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:DEModulation:MDEPth:DELTa:MODE value: enums.DeltaMode = driver.configure.afRf.measurement.demodulation.modDepth.delta.get_mode()
Sets the mode for the reference value of the modulation depth for AM demodulation.
- return:
mode: NONE | MEAS | USER NONE No reference value, delta measurement is disabled MEAS Measured reference value USER User-defined reference value
- get_user() float [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:DEModulation:MDEPth:DELTa:USER value: float = driver.configure.afRf.measurement.demodulation.modDepth.delta.get_user()
Configures the user-defined reference value of the modulation depth for AM demodulation.
- return:
user_val: Range: 0.01 % to 100.00 % , Unit: %
- set_mode(mode: DeltaMode) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:DEModulation:MDEPth:DELTa:MODE driver.configure.afRf.measurement.demodulation.modDepth.delta.set_mode(mode = enums.DeltaMode.MEAS)
Sets the mode for the reference value of the modulation depth for AM demodulation.
- param mode:
NONE | MEAS | USER NONE No reference value, delta measurement is disabled MEAS Measured reference value USER User-defined reference value
- set_user(user_val: float) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:DEModulation:MDEPth:DELTa:USER driver.configure.afRf.measurement.demodulation.modDepth.delta.set_user(user_val = 1.0)
Configures the user-defined reference value of the modulation depth for AM demodulation.
- param user_val:
Range: 0.01 % to 100.00 % , Unit: %
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.configure.afRf.measurement.demodulation.modDepth.delta.clone()
Subgroups