Sinad
SCPI Command:
CONFigure:AFRF:MEASurement<Instance>:MEValuation:LIMit:AIN<Nr>:SINad
- class SinadCls[source]
Sinad commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class SinadStruct[source]
Response structure. Fields:
Enable: bool: OFF | ON Enables or disables the limit check
Lower: float: Lower SINAD limit Range: 0 dB to 140 dB, Unit: dB
Upper: float: Upper SINAD limit Range: 0 dB to 140 dB, Unit: dB
- get(audioInput=AudioInput.Default) SinadStruct [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:LIMit:AIN<Nr>:SINad value: SinadStruct = driver.configure.afRf.measurement.multiEval.limit.audioInput.sinad.get(audioInput = repcap.AudioInput.Default)
Configures limits for the SINAD results, measured via an AF input path.
- param audioInput:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘AudioInput’)
- return:
structure: for return value, see the help for SinadStruct structure arguments.
- set(enable: bool, lower: float, upper: float = None, audioInput=AudioInput.Default) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:LIMit:AIN<Nr>:SINad driver.configure.afRf.measurement.multiEval.limit.audioInput.sinad.set(enable = False, lower = 1.0, upper = 1.0, audioInput = repcap.AudioInput.Default)
Configures limits for the SINAD results, measured via an AF input path.
- param enable:
OFF | ON Enables or disables the limit check
- param lower:
Lower SINAD limit Range: 0 dB to 140 dB, Unit: dB
- param upper:
Upper SINAD limit Range: 0 dB to 140 dB, Unit: dB
- param audioInput:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘AudioInput’)