PePower
SCPI Command:
CONFigure:AFRF:MEASurement<Instance>:MEValuation:LIMit:RFCarrier:PEPower
- class PePowerCls[source]
PePower commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class PePowerStruct[source]
Response structure. Fields:
Enable_Limit: bool: OFF | ON Enables or disables the limit check
Lower: float: Lower power limit Range: -130 dBm to 55 dBm, Unit: dBm
Upper: float: Upper power limit Range: -130 dBm to 55 dBm, Unit: dBm
- get() PePowerStruct [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:LIMit:RFCarrier:PEPower value: PePowerStruct = driver.configure.afRf.measurement.multiEval.limit.rfCarrier.pePower.get()
Configures limits for the measured RF signal power (PEP value) .
- return:
structure: for return value, see the help for PePowerStruct structure arguments.
- set(enable_limit: bool, lower: float, upper: float) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:LIMit:RFCarrier:PEPower driver.configure.afRf.measurement.multiEval.limit.rfCarrier.pePower.set(enable_limit = False, lower = 1.0, upper = 1.0)
Configures limits for the measured RF signal power (PEP value) .
- param enable_limit:
OFF | ON Enables or disables the limit check
- param lower:
Lower power limit Range: -130 dBm to 55 dBm, Unit: dBm
- param upper:
Upper power limit Range: -130 dBm to 55 dBm, Unit: dBm