Tpause
SCPI Command:
CONFigure:AFRF:MEASurement<Instance>:MEValuation:LIMit:TONes:SCAL:TPAuse
- class TpauseCls[source]
Tpause commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class TpauseStruct[source]
Response structure. Fields:
Enable: bool: OFF | ON Enables or disables the limit check
Lower: float: Lower pause limit Range: 0.1 s to 0.25 s, Unit: s
Upper: float: Upper pause limit Range: 0.25 s to 3 s, Unit: s
- get() TpauseStruct [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:LIMit:TONes:SCAL:TPAuse value: TpauseStruct = driver.configure.afRf.measurement.multiEval.limit.tones.scal.tpause.get()
Configures limits for the pause between two dual tones of an analyzed SELCAL sequence.
- return:
structure: for return value, see the help for TpauseStruct structure arguments.
- set(enable: bool, lower: float, upper: float) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:LIMit:TONes:SCAL:TPAuse driver.configure.afRf.measurement.multiEval.limit.tones.scal.tpause.set(enable = False, lower = 1.0, upper = 1.0)
Configures limits for the pause between two dual tones of an analyzed SELCAL sequence.
- param enable:
OFF | ON Enables or disables the limit check
- param lower:
Lower pause limit Range: 0.1 s to 0.25 s, Unit: s
- param upper:
Upper pause limit Range: 0.25 s to 3 s, Unit: s