Demodulation

SCPI Command:

CONFigure:AFRF:MEASurement<Instance>:MEValuation:OSCilloscope:DEModulation:XDIVision
CONFigure:AFRF:MEASurement<Instance>:MEValuation:OSCilloscope:DEModulation:MTIMe
class DemodulationCls[source]

Demodulation commands group definition. 2 total commands, 0 Subgroups, 2 group commands

get_mtime() float[source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:OSCilloscope:DEModulation:MTIMe
value: float = driver.configure.afRf.measurement.multiEval.oscilloscope.demodulation.get_mtime()

Query the measurement time per input path. The measurement time is the time covered by one complete result trace (10 x-axis divisions) .

return:

meas_time: Unit: s

get_xdivision() Xdivision[source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:OSCilloscope:DEModulation:XDIVision
value: enums.Xdivision = driver.configure.afRf.measurement.multiEval.oscilloscope.demodulation.get_xdivision()

Configures the x-axis division of the oscilloscope result diagram. The measurement time equals 10 divisions.

return:

xdivision: U1 | U2 | U5 | U10 | U20 | U50 | U100 | U200 | U500 | M1 | M2 | M5 | M10 | M20 | M50 | M100 | M200 | M500 | S1 Duration of one division. The letters indicate the unit as follows: U = us, M=ms, S=s Example: U20 = 20 us/division

set_mtime(meas_time: float) None[source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:OSCilloscope:DEModulation:MTIMe
driver.configure.afRf.measurement.multiEval.oscilloscope.demodulation.set_mtime(meas_time = 1.0)

Query the measurement time per input path. The measurement time is the time covered by one complete result trace (10 x-axis divisions) .

param meas_time:

Unit: s

set_xdivision(xdivision: Xdivision) None[source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:OSCilloscope:DEModulation:XDIVision
driver.configure.afRf.measurement.multiEval.oscilloscope.demodulation.set_xdivision(xdivision = enums.Xdivision.M1)

Configures the x-axis division of the oscilloscope result diagram. The measurement time equals 10 divisions.

param xdivision: