Fdialing
SCPI Command:
CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:CFGenerator
CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:EFRequency
CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:TTYPe
CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:SLENgth
CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:MACCuracy
CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:DTLength
- class FdialingCls[source]
Fdialing commands group definition. 9 total commands, 1 Subgroups, 6 group commands
- get_cfgenerator() bool [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:CFGenerator value: bool = driver.configure.afRf.measurement.multiEval.tones.fdialing.get_cfgenerator()
Couples the free-dialing tone settings of the analyzer to the corresponding generator settings.
- return:
conf_from_gen: OFF | ON
- get_dt_length() float [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:DTLength value: float = driver.configure.afRf.measurement.multiEval.tones.fdialing.get_dt_length()
Sets or queries the minimum length of a single tone that the dialing measurement can detect.
- return:
dt_length: No help available
- get_efrequency() ExpFrequency [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:EFRequency value: enums.ExpFrequency = driver.configure.afRf.measurement.multiEval.tones.fdialing.get_efrequency()
No command help available
- return:
exp_frequency: No help available
- get_maccuracy() MeasAccuracy [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:MACCuracy value: enums.MeasAccuracy = driver.configure.afRf.measurement.multiEval.tones.fdialing.get_maccuracy()
Configures the accuracy of the analysis of free-dialing single-tone sequences.
- return:
meas_accuracy: NORMal | HIGH NORMal: lower tone detection accuracy / minimum pause length HIGH: higher tone detection accuracy / minimum pause length
- get_slength() int [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:SLENgth value: int = driver.configure.afRf.measurement.multiEval.tones.fdialing.get_slength()
Specifies the expected length of the analyzed free-dialing tone sequence (number of digits) .
- return:
seq_length: Range: 1 to 42
- get_ttype() SingDualToneType [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:TTYPe value: enums.SingDualToneType = driver.configure.afRf.measurement.multiEval.tones.fdialing.get_ttype()
Selects a tone type for free-dialing tone sequence analysis.
- return:
tone_type: STONe | DTONe Single tones or dual tones
- set_cfgenerator(conf_from_gen: bool) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:CFGenerator driver.configure.afRf.measurement.multiEval.tones.fdialing.set_cfgenerator(conf_from_gen = False)
Couples the free-dialing tone settings of the analyzer to the corresponding generator settings.
- param conf_from_gen:
OFF | ON
- set_dt_length(dt_length: float) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:DTLength driver.configure.afRf.measurement.multiEval.tones.fdialing.set_dt_length(dt_length = 1.0)
Sets or queries the minimum length of a single tone that the dialing measurement can detect.
- param dt_length:
numeric value Range: 0.02 to 0.03 , Unit: s
- set_efrequency(exp_frequency: ExpFrequency) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:EFRequency driver.configure.afRf.measurement.multiEval.tones.fdialing.set_efrequency(exp_frequency = enums.ExpFrequency.CONF)
No command help available
- param exp_frequency:
No help available
- set_maccuracy(meas_accuracy: MeasAccuracy) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:MACCuracy driver.configure.afRf.measurement.multiEval.tones.fdialing.set_maccuracy(meas_accuracy = enums.MeasAccuracy.HIGH)
Configures the accuracy of the analysis of free-dialing single-tone sequences.
- param meas_accuracy:
NORMal | HIGH NORMal: lower tone detection accuracy / minimum pause length HIGH: higher tone detection accuracy / minimum pause length
- set_slength(seq_length: int) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:SLENgth driver.configure.afRf.measurement.multiEval.tones.fdialing.set_slength(seq_length = 1)
Specifies the expected length of the analyzed free-dialing tone sequence (number of digits) .
- param seq_length:
Range: 1 to 42
- set_ttype(tone_type: SingDualToneType) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:MEValuation:TONes:FDIaling:TTYPe driver.configure.afRf.measurement.multiEval.tones.fdialing.set_ttype(tone_type = enums.SingDualToneType.DTONe)
Selects a tone type for free-dialing tone sequence analysis.
- param tone_type:
STONe | DTONe Single tones or dual tones
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.configure.afRf.measurement.multiEval.tones.fdialing.clone()
Subgroups