Delta
SCPI Command:
CONFigure:AFRF:MEASurement<Instance>:RFCarrier:POWer:DELTa:MODE
CONFigure:AFRF:MEASurement<Instance>:RFCarrier:POWer:DELTa:USER
CONFigure:AFRF:MEASurement<Instance>:RFCarrier:POWer:DELTa:MEASured
- class DeltaCls[source]
Delta commands group definition. 4 total commands, 1 Subgroups, 3 group commands
- get_measured() float [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:RFCarrier:POWer:DELTa:MEASured value: float = driver.configure.afRf.measurement.rfCarrier.power.delta.get_measured()
Configures the measured reference value for power root mean square.
- return:
meas_val: Unit: dBm
- get_mode() DeltaMode [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:RFCarrier:POWer:DELTa:MODE value: enums.DeltaMode = driver.configure.afRf.measurement.rfCarrier.power.delta.get_mode()
Configures the reference mode for carrier power root mean square.
- return:
mode: NONE | MEAS | USER
- get_user() float [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:RFCarrier:POWer:DELTa:USER value: float = driver.configure.afRf.measurement.rfCarrier.power.delta.get_user()
Configures the user reference value for power root mean square.
- return:
user_val: Unit: dBm
- set_mode(mode: DeltaMode) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:RFCarrier:POWer:DELTa:MODE driver.configure.afRf.measurement.rfCarrier.power.delta.set_mode(mode = enums.DeltaMode.MEAS)
Configures the reference mode for carrier power root mean square.
- param mode:
NONE | MEAS | USER
- set_user(user_val: float) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:RFCarrier:POWer:DELTa:USER driver.configure.afRf.measurement.rfCarrier.power.delta.set_user(user_val = 1.0)
Configures the user reference value for power root mean square.
- param user_val:
Unit: dBm
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.configure.afRf.measurement.rfCarrier.power.delta.clone()
Subgroups