LrfLevel
SCPI Command:
CONFigure:AFRF:MEASurement<Instance>:SROutines:LRFLevel
- class LrfLevelCls[source]
LrfLevel commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class LrfLevelStruct[source]
Response structure. Fields:
Enabled: bool: OFF | ON
Min_Level: float: Unit: dBm
- get() LrfLevelStruct [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:SROutines:LRFLevel value: LrfLevelStruct = driver.configure.afRf.measurement.searchRoutines.lrfLevel.get()
Configures the minimum RF level for the signal generator.
- return:
structure: for return value, see the help for LrfLevelStruct structure arguments.
- set(enabled: bool, min_level: float) None [source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:SROutines:LRFLevel driver.configure.afRf.measurement.searchRoutines.lrfLevel.set(enabled = False, min_level = 1.0)
Configures the minimum RF level for the signal generator.
- param enabled:
OFF | ON
- param min_level:
Unit: dBm