Hpass

SCPI Command:

CONFigure:AFRF:MEASurement<Instance>:SIN:FILTer:HPASs
class HpassCls[source]

Hpass commands group definition. 1 total commands, 0 Subgroups, 1 group commands

class HpassStruct[source]

Response structure. Fields:

  • Filter_Left: enums.HighpassFilterExtended: OFF | F6 | F50 | F300 Left SPDIF channel OFF Filter disabled F6, F50, F300 Cutoff frequency 6 Hz / 50 Hz / 300 Hz

  • Filter_Right: enums.HighpassFilterExtended: OFF | F6 | F50 | F300 Right SPDIF channel

get() HpassStruct[source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:SIN:FILTer:HPASs
value: HpassStruct = driver.configure.afRf.measurement.spdif.filterPy.hpass.get()

Configures the highpass filter in the SPDIF input path.

return:

structure: for return value, see the help for HpassStruct structure arguments.

set(filter_left: HighpassFilterExtended, filter_right: HighpassFilterExtended) None[source]
# SCPI: CONFigure:AFRF:MEASurement<Instance>:SIN:FILTer:HPASs
driver.configure.afRf.measurement.spdif.filterPy.hpass.set(filter_left = enums.HighpassFilterExtended.F300, filter_right = enums.HighpassFilterExtended.F300)

Configures the highpass filter in the SPDIF input path.

param filter_left:

OFF | F6 | F50 | F300 Left SPDIF channel OFF Filter disabled F6, F50, F300 Cutoff frequency 6 Hz / 50 Hz / 300 Hz

param filter_right:

OFF | F6 | F50 | F300 Right SPDIF channel