Value
SCPI Command:
CONFigure:GPRF:MEASurement<Instance>:NRT:REVerse:VALue:ENABle
- class ValueCls[source]
Value commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get_enable() DirPwrSensorRevValue [source]
# SCPI: CONFigure:GPRF:MEASurement<Instance>:NRT:REVerse:VALue:ENABle value: enums.DirPwrSensorRevValue = driver.configure.gprfMeasurement.nrt.reverse.value.get_enable()
- Selects the reverse result to be measured.
INTRO_CMD_HELP: The effect of the value RPWR depends on the value set via the command method RsCma.Configure.GprfMeasurement.Nrt.Forward.Value.enable:
FPWR or PEP: RPWR selects the reverse power result
CFAC or CCDF: RPWR selects the forward power result
- return:
value: RPWR | RLOS | REFL | SWR RPWR Reverse power or forward power RLOS Return loss REFL Reflection SWR Standing wave ratio
- set_enable(value: DirPwrSensorRevValue) None [source]
# SCPI: CONFigure:GPRF:MEASurement<Instance>:NRT:REVerse:VALue:ENABle driver.configure.gprfMeasurement.nrt.reverse.value.set_enable(value = enums.DirPwrSensorRevValue.REFL)
- Selects the reverse result to be measured.
INTRO_CMD_HELP: The effect of the value RPWR depends on the value set via the command method RsCma.Configure.GprfMeasurement.Nrt.Forward.Value.enable:
FPWR or PEP: RPWR selects the reverse power result
CFAC or CCDF: RPWR selects the forward power result
- param value:
RPWR | RLOS | REFL | SWR RPWR Reverse power or forward power RLOS Return loss REFL Reflection SWR Standing wave ratio