from .....Internal.Core import Core
from .....Internal.CommandsGroup import CommandsGroup
from .....Internal.StructBase import StructBase
from .....Internal.ArgStruct import ArgStruct
from ..... import enums
# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs]class CurrentCls:
"""Current commands group definition. 3 total commands, 0 Subgroups, 3 group commands"""
def __init__(self, core: Core, parent):
self._core = core
self._cmd_group = CommandsGroup("current", core, parent)
# noinspection PyTypeChecker
[docs] class CalculateStruct(StructBase):
"""Response structure. Fields: \n
- Reliability: int: See 'Reliability indicator values'
- Power: enums.ResultStatus: Reverse power or forward power Unit: dBm
- Return_Loss: enums.ResultStatus: Unit: dB
- Reflection: enums.ResultStatus: Unit: %
- Swr: enums.ResultStatus: Standing wave ratio"""
__meta_args_list = [
ArgStruct.scalar_int('Reliability', 'Reliability'),
ArgStruct.scalar_enum('Power', enums.ResultStatus),
ArgStruct.scalar_enum('Return_Loss', enums.ResultStatus),
ArgStruct.scalar_enum('Reflection', enums.ResultStatus),
ArgStruct.scalar_enum('Swr', enums.ResultStatus)]
def __init__(self):
StructBase.__init__(self, self)
self.Reliability: int = None
self.Power: enums.ResultStatus = None
self.Return_Loss: enums.ResultStatus = None
self.Reflection: enums.ResultStatus = None
self.Swr: enums.ResultStatus = None
[docs] def calculate(self) -> CalculateStruct:
"""SCPI: CALCulate:GPRF:MEASurement<Instance>:NRT:REVerse:CURRent \n
Snippet: value: CalculateStruct = driver.gprfMeasurement.nrt.reverse.current.calculate() \n
Return the measurement results for the reverse direction.
INTRO_CMD_HELP: The meaning of the result <Power> depends on the value set via the command method RsCma.Configure.GprfMeasurement.Nrt.Forward.Value.enable: \n
- FPWR or PEP: <Power> is the reverse power.
- CFAC or CCDF: <Power> is the forward power.
CALCulate commands return error indicators instead of measurement values. \n
:return: structure: for return value, see the help for CalculateStruct structure arguments."""
return self._core.io.query_struct(f'CALCulate:GPRF:MEASurement<Instance>:NRT:REVerse:CURRent?', self.__class__.CalculateStruct())
# noinspection PyTypeChecker
[docs] class ResultData(StructBase):
"""Response structure. Fields: \n
- Reliability: int: See 'Reliability indicator values'
- Power: float: Reverse power or forward power Unit: dBm
- Return_Loss: float: Unit: dB
- Reflection: float: Unit: %
- Swr: float: Standing wave ratio"""
__meta_args_list = [
ArgStruct.scalar_int('Reliability', 'Reliability'),
ArgStruct.scalar_float('Power'),
ArgStruct.scalar_float('Return_Loss'),
ArgStruct.scalar_float('Reflection'),
ArgStruct.scalar_float('Swr')]
def __init__(self):
StructBase.__init__(self, self)
self.Reliability: int = None
self.Power: float = None
self.Return_Loss: float = None
self.Reflection: float = None
self.Swr: float = None
[docs] def fetch(self) -> ResultData:
"""SCPI: FETCh:GPRF:MEASurement<Instance>:NRT:REVerse:CURRent \n
Snippet: value: ResultData = driver.gprfMeasurement.nrt.reverse.current.fetch() \n
Return the measurement results for the reverse direction.
INTRO_CMD_HELP: The meaning of the result <Power> depends on the value set via the command method RsCma.Configure.GprfMeasurement.Nrt.Forward.Value.enable: \n
- FPWR or PEP: <Power> is the reverse power.
- CFAC or CCDF: <Power> is the forward power.
CALCulate commands return error indicators instead of measurement values. \n
:return: structure: for return value, see the help for ResultData structure arguments."""
return self._core.io.query_struct(f'FETCh:GPRF:MEASurement<Instance>:NRT:REVerse:CURRent?', self.__class__.ResultData())
[docs] def read(self) -> ResultData:
"""SCPI: READ:GPRF:MEASurement<Instance>:NRT:REVerse:CURRent \n
Snippet: value: ResultData = driver.gprfMeasurement.nrt.reverse.current.read() \n
Return the measurement results for the reverse direction.
INTRO_CMD_HELP: The meaning of the result <Power> depends on the value set via the command method RsCma.Configure.GprfMeasurement.Nrt.Forward.Value.enable: \n
- FPWR or PEP: <Power> is the reverse power.
- CFAC or CCDF: <Power> is the forward power.
CALCulate commands return error indicators instead of measurement values. \n
:return: structure: for return value, see the help for ResultData structure arguments."""
return self._core.io.query_struct(f'READ:GPRF:MEASurement<Instance>:NRT:REVerse:CURRent?', self.__class__.ResultData())